3 Phase Precision Power Analyzer - VPA 60080

INTRODUCTION OF 3 Phase Precision Power Analyzer - VPA 60080

3 Phase Power Analyzer
3 Phase Power Analyzer
3 Phase Power Analyzer
3 Phase Power Analyzer
3 Phase Power Analyzer
3 Phase Power Analyzer
3 Phase Power Analyzer - VPAe
  • Description
  • Key Features
  • Application
  • Scope Of Measurement
  • General Specifications
  • Measurement Functions
  • Various Available Options
  • Specification For Extra Channels

VEER Power Analyzer VPA-60080 is result of continuous R & D activities. It is an accurate Instrument to test 3 Phase & 1 Phase electrical Machines due to high sampling rate & simultaneous measurement of parameters. It has no adjustable components inside so, accuracy remains long time. We provide Free Software "VEER POWER ANALYZER TOOL" with VPA-60080 to communicate with computer which is capable to collect all parameters from VPA-60080 & generates test report. You can see parameters in different view like Digital, Analog, Graphical etc in real time. You can record test data in real time to eliminates Human error in Testing.

  • TRMS Voltage 600V/1200V/1400V Phase, 1050V/ 2100V/2400V Line
  • TRMS Current 80A / 160A / 300A Direct
  • 500 Test Data Storage Inbuilt (1000 Optional)
  • USB, RS-232 / RS-485 interface & Free Software
  • 20 X 4 Jumbo LCD & Ultra Glow Red LED Display
  • High Speed Measurement in 0.25 Sec (Optional)
  • Torque, RPM, %Slip, Eff. Measurement (Motor Version)
  • Flow, Head, RPM, %Slip Measurement (Pump Version)
  • Auto over Voltage Shutdown Facility (Optional)
  • Inbuilt Surge Protection in Selective Models
  • Double Fuse Protection
  • 2 Wattmeter, 3 Wattmeter Measurement Facility
  • 2 in 1 Rack Mountable & Table Top Model
  • User Friendly Operation with embossed Key Pad
  • Tamper Proof Calibration & Long term stability
  • NABL certified in EQDC & ERDA
  • CT-PT Ratio Setting Facility (Optional)
  • To Perform No Load, Load Test of 1-Ph & 3-Ph Distribution, Power, Control, Isolation & other Transformers.
  • To Perform No Load, Load, Block Rotor & Efficiency Test of Motors & Pumps.
  • To Test LED Light, Stabilizer, Air conditioner, Fan, Heater, Ballast, Cooler etc. domestic appliances.
  • To calibrate Voltmeter, Amp meter, Watt meter, PF meter, Power source etc.
  • Educational Institutes, Degree / Diploma / ITI colleges in Electrical & Electronics Department.
  • To monitor power condition at renewable energy generation, Mega Mall, Mobile Base station etc.
  • TRMS, Mean, Rectified and Peak, Crest Factor, Form Factor of Voltage and Current.
  • Active Power (P), Apparent Power(S) and Reactive Power (Q), Power Factor, Frequency accurately.
  • Torque, RPM, %Slip, Output Power, Direct Efficiency of Motor (Motor Version)
  • Flow, Pressure, Suction, %Slip, RPM of Pump (Pump Version).
GENERAL SPECIFICATIONS
Warm up time 30 minutes
Operating temperature 5 C to 50 C
Operating humidity 20% to 80% RH (no condensation)
Storage temperature 0 C to 55 C
Power supply 160V - 290V @ 50Hz / 100V - 140V @ 60 Hz
Power consumption 30VA Max
Dimension 376 x 320 x 145 mm (W x D x H)**
Panel cut out size 332 x 133 mm without Feet**
Weight 5.5 kg approximately**
Input Terminal Type Voltage : Banana socket (wire fit type)
Current : large binding Post (1/4 or 6/16 copper stud with insulated nut)
 
Measurement Functions
Parameter Voltage / Current/ Active power
                          Accuracy 
(Within 1 Year after Calibration *)
Condition:-
Temperature  : 25 ˚C ± 5 ˚C
Humidity         : 30 – 75% RH 
Input                : Sine Wave 
Power factor  : 1.0
Display digits  : 5 / 6 digits
Sample Avg     : 10 Sample 
*Normal test & input condition       
Frequency Range Accuracy




45 Hz to 62Hz




±(0.1% Reading ± 0.1%Range)


Peak / Mean = Above x 2 
Additional PF effect on Active  Power Measurement   At 50Hz 0.035˚ or Time delay errors 2.5 µs
Effective Input range  10-100% of Voltage, 1-100% current range rating 
Display updating value  0.25 to 10 seconds in selected models 

Frequency Measurement 
For input > = 3% of VI 45 to 65 Hz Accuracy ± 0.05% Frequency between VI Input & Neutral Terminal  
  • High Speed Measurement up to 250 ms Update rate
  • Voltage Range 150V / 300V / 600V / 1200V / 1400V
  • Current Range 1A / 8A / 20A / 40A / 80A / 160A / 300A
  • CT Ratio (Up to 250) & PT Ratio (Up to 600) Setting (Other ranges available on request)
  • Flow, Pressure, RPM, Torque, Efficiency for Motor & Pump
  • AC-DC Measurement
SPECIFICATIONS OF EXTRA CHANNELS
Parameters Measuring Range Accuracy / Remark
Flow,Pressure 4-20 mA ± 0.20 % on FSD
Torque Depends on Sensor ± 0.20 % on FSD
RPM Depends on Sensor ± 0.1 % on FSD

Note :

  • 1. Above all Specifications are subject to change without prior notice, So please confirm at the time of placing order.
  • 2. *Size and Weight may be change without prior notice for continuous development.
  • 3. 12 months for manufacturing defects only at Ex Works No Warranty of any accessories.
Whatsapp Us